Services
All your fire protection needs, handled for you
One company for the entire code cycle — inspection, service, rebuilds, testing and new equipment. We track your due dates so you never get caught with an expired tag.
01
Annual inspection & service
The yearly maintenance every extinguisher in your building is required to have.
DetailsWe inspect, service and re-tag every extinguisher on site. Gauges, hoses, pins, seals, shells, brackets and signage all get checked, and anything that needs correcting gets corrected the same visit wherever possible.
- Full external examination of every unit
- Weigh, inspect and recharge as needed
- New certification tag applied on the spot
- Written record of every unit and its next due date
Stored-pressure dry chemical extinguishers have to come apart every six years for an internal examination. We empty the unit, inspect the shell and valve internally, replace worn parts, recharge and re-seal it.
- Full internal examination per NFPA 10
- Valve, o-ring and gasket replacement
- Recharge with fresh agent
- Swap-out units available so you are never without coverage
At twelve years the cylinder itself has to be pressure-tested to prove it can still safely hold its charge. Units that pass are rebuilt, recharged and returned. Units that fail get replaced, and we will tell you which is cheaper before we start.
- Hydrostatic pressure test of the cylinder
- Rebuild and recharge on passing units
- Honest replace-vs-test recommendation
- Loaner units during testing
We sell and install ABC dry chemical, CO2, Class K wet chemical and water mist extinguishers, plus brackets, cabinets and signage. We size them to your hazard and your square footage, not to whatever is on the truck.
- ABC, CO2, Class K and water mist units
- Brackets, cabinets, covers and signage
- Mounted and tagged at installation
- Sized to your hazard class and travel distances
05
Swap & exchange program
For year six and year twelve, we bring a serviced unit and take yours away.
DetailsInstead of leaving a gap on your wall while a unit is in the shop, we bring an already-serviced, fully-certified extinguisher, hang it, and take yours with us. Your coverage never lapses and your staff never has to think about it.
- No gap in coverage during rebuild or testing
- Certified replacement hung the same visit
- Ideal for year 6 and year 12 cycles
- One flat, quoted price
How the cycle works
One, six and twelve
Every portable extinguisher in Tennessee runs on the same basic schedule. We keep track of where each of your units sits.
Every 1 year
Annual maintenance & service
Every portable extinguisher gets a full external examination, service and a new certification tag.
Every 6 years
Internal examination & rebuild
Stored-pressure units are emptied, examined internally, rebuilt with new seals and recharged.
Every 12 years
Hydrostatic test & rebuild
The cylinder is pressure-tested to confirm it can still safely hold its charge, then rebuilt and recharged.
Per NFPA 10 (2022 Edition). See the full compliance breakdown.
No reason to delay
Submit one short form and we will give you a free, guaranteed, exact-price bid before we do any work.